1. <th id="p2utc"></th>
      1. Low voltage power distribution, agricultural class

        DC screen

        Views:

        System model definition


        The natural environment
        Height: 2000m
        Environment temperature: -5 ℃ -+50 ℃
        Relative humidity: ≤ 90% (20 ± 5 ℃)
        Non conductive and explosive dust, non corrosive gas
        No violent vibration and impact
        The use of indoor and ventilated

        System parameters
        Precision: within 0.5%
        Current stabilizing precision: within 0.5%
        Ripple factor: ≤ ± 0.1%
        Power factor: = 0.92
        Efficiency: = 94%
        Noise: ≤ 45Db
        Current sharing Unbalance: ≤ 3%
        The reliability index: MTBF = 100000h
        AC input voltage range: 380V ± 15%
        The AC voltage frequency range: 50HZ ± 10%


        Scope of application
        Power 'M is functional integration of DC power supply system in our company is suitable for DC system of 200Ah and below, can be installed 4 K4810 (K4A20) module, which can provide 220V / 40A (110V / 80A).

        System features
        ● used to form 200Ah and DC system below, for, small transformer substation. Can be installed up to 4 K4810 (K4A20) module, which can provide 220V / 40A{110V / 80A).
        ● rectifier module maximum configuration module for 1 control female power.
        ● module and monitoring unit adopts electric plug structure, installation, convenient maintenance.
        ● module and monitoring unit in a bracket, compact structure.
        ● monitoring has been completed parenting voltage, voltage controlled current controlling mother, mother, battery charging and discharging current detection, no external sensing.
        The monitoring unit has a level 5 or 7 grade silicon chain pressure automatic control function, only with the silicon chain can realize the control of parent automatic voltage regulator.
        The monitoring unit adopts LCD display, Chinese characters menu, key operation, can realize the system parameter setting, parameter display, system fault indicator and system calibration.
        The monitoring unit has the function of automatic management of battery.
        The monitoring unit provides RS232 / RS485 communication interface, built-in CDT and ModbuS two communication protocol, can be connected with the power plant automation system.


        Technical parameters of the system
        AC input: AC380V ± 20% grid frequency: 50Hz ± 10%
        Power factor: ≥ 0.92 input over-voltage protection: 380 ± 20%
        Precision: ≤ ± 0.5% current stabilizing precision: within 0.5%
        Efficiency: ≥ 94% ripple coefficient: ≤ 0.1%
        Insulation resistance: = 10M Ω audible noise: ≤ 55dB
        Environment temperature: -5 ℃ ~+45 ℃, relative humidity: ≤ 90% (20 ± 5 ℃)
        Dielectric strength: 2KVAC minutes without flashover, no breakdown
        Output voltage: 180V~270V set (220V system)
        90V~135V set (110V system)
        Output current: 20A~40A (220V system with 2-4 rectifier module)
        40A~80A (110V system with 2-4 rectifier module)
        Battery capacity: 65Ah~200Ah (220V system)
        100Ah~300Ah (110V system)
        Battery charging management: automatic
        Battery temperature compensation: batteries inspection can be realized
        Body size: 800 x 600 x 2260 or 800 x 600 x 2360
        The system wiring scheme: GZDW33 and GZDW35

        System options
        The selection of equipment
        Scheme selection
        Program description
        The main control unit of PS2 system
        Will accessories
        This scheme suitable for DC system of 200Ah and below, single bus not segment for, single group battery system; can configure 1 module is used to control the master power supply. Many feeder output system can feed cabinet configuration independent.
        K4B10 (K4A20) rectifier module
        The feeder output
        Charging cabinet
        Battery cabinet
        PM3A communication control unit
        Optional accessories
        PM2J/PM3J insulation monitoring unit
        PM2B battery checking unit
        KD2B10 (KD2A15) reducing module